Source

SCPI Command :

MEASurement<*>:SOURce
Commands in total: 1
Subgroups: 0
Direct child commands: 1
class SourceStruct[source]

Response structure. Fields:

  • 1 Signal_Source: enums.SignalSource: NONE | C1 | C2 | … | C8 | D0 | D1 | D2 | … | D14 | D15 | M1 | M2 | … | M8 | TRK1 | TRK2 | TRK3 | … | TRK24 | HWAVeform1 | HWAVeform2 | … | HWAVeform8 | PA1QPOWER | PA2QPOWER | … | PA6QPOWER | PA1HPOWER1 | PA2HPOWER1 | … | PA6HPOWER1| | PA1SPOWER | PA2SPOWER | … | PA6SPOWER | PA1SOA | PA2SOA | … | PA6SOA | PA1IPOWER | PA2IPOWER | … | PA6IPOWER | PA1OPOWER1 | PA2OPOWER1 | … | PA6OPOWER1 | PA1OPOWER2 | PA2OPOWER2 | … | PA6OPOWER2 | PA1OPOWER3 | PA2OPOWER3 | … | PA6OPOWER3 | PTHREE1HPOWER1 | PTHREE2HPOWER1 | … | PTHREE6HPOWER1 | PTHREE1HPOWER2 | PTHREE2HPOWER2 | … | PTHREE6HPOWER2 | PTHREE1HPOWER3 | PTHREE2HPOWER3 | … | PTHREE6HPOWER3 | PTHREE1HTPOWER | PTHREE2HTPOWER | … | PTHREE6HTPOWER | PTHREE1QPOWER1 | PTHREE2QPOWER1 | … | PTHREE6QPOWER1 | PTHREE1QPOWER2 | PTHREE2QPOWER2 | … | PTHREE6QPOWER2 | PTHREE1QPOWER3 | PTHREE2QPOWER3 | … | PTHREE6QPOWER3 | PTHREE1QTPOWER | PTHREE2QTPOWER | … | PTHREE6QTPOWER | PA1TOPOWER | PA2TOPOWER | … | PA6TOPOWER | OnC1 | OnC2 | … | OnC8 (n = 2 to 11

  • 2 Signal_Source_2: enums.SignalSource: Same as SignalSource

get(measIndex=MeasIndex.Default) SourceStruct[source]
# MEASurement<*>:SOURce
value: SourceStruct = driver.measurement.source.get(measIndex = repcap.MeasIndex.Default)

Sets the source of the measurement. The source must fit the selected measurement type. For example, histogram measurements require a waveform histogram as source, and protocol measurements require a serial bus.

Parameters:

measIndex – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

Returns:

structure: for return value, see the help for SourceStruct structure arguments.

set(signal_source: SignalSource, signal_source_2: SignalSource = None, measIndex=MeasIndex.Default) None[source]
# MEASurement<*>:SOURce
driver.measurement.source.set(signal_source = enums.SignalSource.C1, signal_source_2 = enums.SignalSource.C1, measIndex = repcap.MeasIndex.Default)

Sets the source of the measurement. The source must fit the selected measurement type. For example, histogram measurements require a waveform histogram as source, and protocol measurements require a serial bus.

Parameters:
  • signal_source – NONE | C1 | C2 | … | C8 | D0 | D1 | D2 | … | D14 | D15 | M1 | M2 | … | M8 | TRK1 | TRK2 | TRK3 | … | TRK24 | HWAVeform1 | HWAVeform2 | … | HWAVeform8 | PA1QPOWER | PA2QPOWER | … | PA6QPOWER | PA1HPOWER1 | PA2HPOWER1 | … | PA6HPOWER1| | PA1SPOWER | PA2SPOWER | … | PA6SPOWER | PA1SOA | PA2SOA | … | PA6SOA | PA1IPOWER | PA2IPOWER | … | PA6IPOWER | PA1OPOWER1 | PA2OPOWER1 | … | PA6OPOWER1 | PA1OPOWER2 | PA2OPOWER2 | … | PA6OPOWER2 | PA1OPOWER3 | PA2OPOWER3 | … | PA6OPOWER3 | PTHREE1HPOWER1 | PTHREE2HPOWER1 | … | PTHREE6HPOWER1 | PTHREE1HPOWER2 | PTHREE2HPOWER2 | … | PTHREE6HPOWER2 | PTHREE1HPOWER3 | PTHREE2HPOWER3 | … | PTHREE6HPOWER3 | PTHREE1HTPOWER | PTHREE2HTPOWER | … | PTHREE6HTPOWER | PTHREE1QPOWER1 | PTHREE2QPOWER1 | … | PTHREE6QPOWER1 | PTHREE1QPOWER2 | PTHREE2QPOWER2 | … | PTHREE6QPOWER2 | PTHREE1QPOWER3 | PTHREE2QPOWER3 | … | PTHREE6QPOWER3 | PTHREE1QTPOWER | PTHREE2QTPOWER | … | PTHREE6QTPOWER | PA1TOPOWER | PA2TOPOWER | … | PA6TOPOWER | OnC1 | OnC2 | … | OnC8 (n = 2 to 11

  • signal_source_2 – Same as SignalSource

  • measIndex – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)