Source code for rsmxo.Implementations.Probe.Setup.Attenuation.DefProbe

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal import Conversions
from ..... import enums
from ..... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class DefProbeCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("defProbe", core, parent)

[docs] def set(self, select_predef_prb: enums.SelectProbe, probe=repcap.Probe.Default) -> None: """ ``PROBe<*>:SETup:ATTenuation:DEFProbe`` \n Snippet: ``driver.probe.setup.attenuation.defProbe.set(select_predef_prb = enums.SelectProbe.CMN50HF015, probe = repcap.Probe.Default)`` \n Selects one of the predefined probes, or a user-defined probe. :param select_predef_prb: NONE | ZC10 | ZC20 | ZC30 | ZD01A100 | ZD01A1000 | HZ15 | HZ17 | RTZ25C1 | ZZ80 | ZS10L | ZD02 | ZD08 | ZC02100 | ZC021000 | ZC03 | ZD002A10 | ZD002A100 | ZD003A20 | ZD003A200 | ZC3110 | ZC311 | ZC3101 | ZH03 | ZP1X | CWT15 | CWT30 | CWTMN1 | CMN50HF3 | CMN50HF15 | CMN50HF30 | CMN50HF015 | CMN50HF06 | CWTUM015 | CWTUM06 | CWTUM1 | V1V1 | V10V1 | V100V1 | V200V1 | V1000V1 | V1A1000 | V1A100 | V1A10 | V1A1 | USER \n - ZC10 | ZC20 | ZC30 | ZC03: Current probes - ZD02 | ZD08 | ZD01A100 | ZD01A1000 | ZD002A10 | ZD002A100 | ZD003A20 | ZD003A200: Active differential probes, attenuation ratio according to the setting on the probe.A100 = 100:1A1000 = 1000:1 - HZ15 | HZ17: Near field probes (EMI) - ZC02100 | ZC021000 | ZC3110 | ZC311 | ZC3101: Current probes 100 A/V or 1000 A/V according to the setting on the probe. - CWT15 | CWT30 | CWTMN1 | CWTUM015 | CWTUM06 | CWTUM1 | CMN50HF3 | CMN50HF15 | CMN50HF30 | CMN50HF015 | CMN50HF06: PEM Rogowski probes - ZZ80 | ZH03 | ZP1X: Passive probes - V1V1 | V10V1 | V100V1 | V200V1 | V1000V1 | V1A1000 | V1A100 | V1A10 | V1A1: Common gain and attenuation settings if the probe type is not in the list. - USER: Probe is not detected and not known to the instrument. Set unit and attenuation manually. :param probe: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Probe') """ param = Conversions.enum_scalar_to_str(select_predef_prb, enums.SelectProbe) probe_cmd_val = self._cmd_group.get_repcap_cmd_value(probe, repcap.Probe) self._core.io.write(f'PROBe{probe_cmd_val}:SETup:ATTenuation:DEFProbe {param}')
# noinspection PyTypeChecker
[docs] def get(self, probe=repcap.Probe.Default) -> enums.SelectProbe: """ ``PROBe<*>:SETup:ATTenuation:DEFProbe`` \n Snippet: ``value: enums.SelectProbe = driver.probe.setup.attenuation.defProbe.get(probe = repcap.Probe.Default)`` \n Selects one of the predefined probes, or a user-defined probe. :param probe: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Probe') """ probe_cmd_val = self._cmd_group.get_repcap_cmd_value(probe, repcap.Probe) response = self._core.io.query_str(f'PROBe{probe_cmd_val}:SETup:ATTenuation:DEFProbe?') return Conversions.str_to_scalar_enum(response, enums.SelectProbe)