Source code for rsmxo.Implementations.P3Phase.Harmonics.RefLevel.Absolute.Llevel

from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class LlevelCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("llevel", core, parent)

[docs] def set(self, lower_level: float, power3PhaseMeas=repcap.Power3PhaseMeas.Default, refLevel=repcap.RefLevel.Default) -> None: """ ``P3PHase<*>:HARMonics:REFLevel<*>:ABSolute:LLEVel`` \n Snippet: ``driver.p3Phase.harmonics.refLevel.absolute.llevel.set(lower_level = 1.0, power3PhaseMeas = repcap.Power3PhaseMeas.Default, refLevel = repcap.RefLevel.Default)`` \n Sets the lower reference level in absolute values. This is required, e.g., to determine a fall. :param lower_level: -1E+26 to 1E+26 :param power3PhaseMeas: optional repeated capability selector. Default value: Nr1 (settable in the interface 'P3Phase') :param refLevel: optional repeated capability selector. Default value: Nr1 (settable in the interface 'RefLevel') """ param = Conversions.decimal_value_to_str(lower_level) power3PhaseMeas_cmd_val = self._cmd_group.get_repcap_cmd_value(power3PhaseMeas, repcap.Power3PhaseMeas) refLevel_cmd_val = self._cmd_group.get_repcap_cmd_value(refLevel, repcap.RefLevel) self._core.io.write(f'P3PHase{power3PhaseMeas_cmd_val}:HARMonics:REFLevel{refLevel_cmd_val}:ABSolute:LLEVel {param}')
[docs] def get(self, power3PhaseMeas=repcap.Power3PhaseMeas.Default, refLevel=repcap.RefLevel.Default) -> float: """ ``P3PHase<*>:HARMonics:REFLevel<*>:ABSolute:LLEVel`` \n Snippet: ``value: float = driver.p3Phase.harmonics.refLevel.absolute.llevel.get(power3PhaseMeas = repcap.Power3PhaseMeas.Default, refLevel = repcap.RefLevel.Default)`` \n Sets the lower reference level in absolute values. This is required, e.g., to determine a fall. :param power3PhaseMeas: optional repeated capability selector. Default value: Nr1 (settable in the interface 'P3Phase') :param refLevel: optional repeated capability selector. Default value: Nr1 (settable in the interface 'RefLevel') :return: lower_level: -1E+26 to 1E+26 """ power3PhaseMeas_cmd_val = self._cmd_group.get_repcap_cmd_value(power3PhaseMeas, repcap.Power3PhaseMeas) refLevel_cmd_val = self._cmd_group.get_repcap_cmd_value(refLevel, repcap.RefLevel) response = self._core.io.query_str(f'P3PHase{power3PhaseMeas_cmd_val}:HARMonics:REFLevel{refLevel_cmd_val}:ABSolute:LLEVel?') return Conversions.str_to_float(response)