from ....Internal.Core import Core
from ....Internal.CommandsGroup import CommandsGroup
from ....Internal import Conversions
from .... import enums
from .... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class SourceCls:
"""
| Commands in total: 1
| Subgroups: 0
| Direct child commands: 1
"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("source", core, parent)
[docs]
def set(self, source_detailed: enums.TriggerSource, evnt=repcap.Evnt.Default) -> None:
"""
``TRIGger:EVENt<*>:SOURce`` \n
Snippet: ``driver.trigger.event.source.set(source_detailed = enums.TriggerSource.C1, evnt = repcap.Evnt.Default)`` \n
Selects the source of the trigger signal for the selected trigger event. The trigger source works even if it is not
displayed in a diagram. Available sources depend on the trigger sequence setting. If you trigger on a single event, all
inputs can be used as trigger source. If you trigger on a sequence, only analog channels can be set as trigger source for
A, B, and R-events.
:param source_detailed: \n
- C1 | C2 | ... | C8: Available for single event, and A, B and R-events in a trigger sequence
- EXTernanalog | LINE: Available for single event (suffix 1)
- D0 | D1 | D2 | ... | D14 | D15: Digital channels, require MSO option. Available for single event (suffix 1)
- SBUS1 | SBUS2 | SBUS3 | SBUS4: Available if one or more serial protocol options are installed. If the hardware trigger is supported for a protocol, triggering on single event is possible with hardware trigger settings. For all protocols, the software trigger is supported in a A -> Serial bus (event 2) .
:param evnt: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Event')
"""
param = Conversions.enum_scalar_to_str(source_detailed, enums.TriggerSource)
evnt_cmd_val = self._cmd_group.get_repcap_cmd_value(evnt, repcap.Evnt)
self._core.io.write(f'TRIGger:EVENt{evnt_cmd_val}:SOURce {param}')
# noinspection PyTypeChecker
[docs]
def get(self, evnt=repcap.Evnt.Default) -> enums.TriggerSource:
"""
``TRIGger:EVENt<*>:SOURce`` \n
Snippet: ``value: enums.TriggerSource = driver.trigger.event.source.get(evnt = repcap.Evnt.Default)`` \n
Selects the source of the trigger signal for the selected trigger event. The trigger source works even if it is not
displayed in a diagram. Available sources depend on the trigger sequence setting. If you trigger on a single event, all
inputs can be used as trigger source. If you trigger on a sequence, only analog channels can be set as trigger source for
A, B, and R-events.
:param evnt: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Event')
:return: source_detailed: \n
- C1 | C2 | ... | C8: Available for single event, and A, B and R-events in a trigger sequence
- EXTernanalog | LINE: Available for single event (suffix 1)
- D0 | D1 | D2 | ... | D14 | D15: Digital channels, require MSO option. Available for single event (suffix 1)
- SBUS1 | SBUS2 | SBUS3 | SBUS4: Available if one or more serial protocol options are installed. If the hardware trigger is supported for a protocol, triggering on single event is possible with hardware trigger settings. For all protocols, the software trigger is supported in a A -> Serial bus (event 2) .
"""
evnt_cmd_val = self._cmd_group.get_repcap_cmd_value(evnt, repcap.Evnt)
response = self._core.io.query_str(f'TRIGger:EVENt{evnt_cmd_val}:SOURce?')